Home > ELECTRICAL > ROUGH ELECTRICAL > LOAD CENTERS > MAIN LOAD CENTERS - OUTDOOR
Choose a sub category:
100 AMP 125 AMP 200 AMP
Sort By:
Go
Page of 1
Square D QO Circuit Breaker Enclosure LOADCENTER 125A 12SP 24CIRCUIT Eaton BR1020B100RF Load Center
QO 100 amp, outdoor, NEMA type-3R circuit breaker enclosure, accepts QO circuit breakers with factory installed accessories. Solid neutral and ground bar kit PGTA2 included. 120/240 VAC, 22,000 maximum short circuit current rating that is not for use with single pole QO breakers. UL listed. Homeline value pack, plug on neutral. 12 space, 24 circuit. Main breaker Included. 125 A. Rainproof/outdoor. Includes three HOM120 and two HOM230 circuit breakers. Eaton Load Center, 120/240 V, 100 A, Number of Phases: 1, Number of Spaces: 10, Number of Poles: 20, Number of Circuits: 20, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Cable Size: #4-1/0 AWG, Bus Bar Material: Aluminum, Bus Bar Rating: 100 A, Enclosure Type: NEMA 3R, Flush, Surface Mounting
LOADCENTER 100A 20SP 40CIRCUIT Eaton BR816B200RF Load Center PowerMark Gold TM820RCUFLP Load Center
Homeline plug on neutral load center. 20 space, 40 circuit. Main breaker 100 A. Rainproof/outdoor. Eaton Load Center, 120/240 V, 200 A, Number of Phases: 1, Number of Spaces: 8, Number of Poles: 24, Number of Circuits: 16, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Bus Bar Material: Aluminum, Bus Bar Rating: 200 A, Enclosure Type: NEMA 3R, Flush, Surface Mounting GE load centers lower your costs by making installation faster and easier and by increasing application flexibility. At the same time, they deliver obvious and significant advances in design, function and quality.
ENCLOSURE MAIN BREAKER 2P 200A Square D QO Circuit Breaker Enclosure LOAD CNTR 200A 20SP 32C OUTDOR
Galvanized steel outdoor enclosure. CCVH factory installed (25 kAIC) Circuit breaker. 2/0 to 300 kcmil wire size range. Approved for use as a service entrance. 2-pole 200 A. Outdoor circuit breaker enclosure, 200 A. NEMA type 3R for exterior use. Includes a QOM2200VH circuit breaker and a QOM22225NRB enclosure. UL listed. GE load centers lower your costs by making installation faster and easier and by increasing application flexibility. At the same time, they deliver obvious and significant advances in design, function and quality.
LOADCENTER 200A 30SP 60CIRCUIT Eaton BR2040B200R Load Center Eaton BR3040B200R Load Center
Homeline value pack. Plug on neutral. 30 space, 60 circuit. Main breaker Included. 200 A. Rainproof/outdoor. Includes three HOM120 and two HOM230 circuit breakers. Eaton Load Center, 120/240 V, 200 A, Number of Phases: 1, Number of Spaces: 20, Number of Poles: 40, Number of Circuits: 40, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Cable Size: #2-300 kcmil, Bus Bar Material: Aluminum, Bus Bar Rating: 200 A, Enclosure Type: NEMA 3R, Flush, Surface Mounting Eaton Load Center, 120/240 V, 200 A, Number of Phases: 1, Number of Spaces: 30, Number of Poles: 60, Number of Circuits: 60, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Cable Size: #2-300 kcmil, Bus Bar Material: Aluminum, Bus Bar Rating: 200 A, Enclosure Type: NEMA 3R, Flush, Surface Mounting
Square D QO130M200PRB QO Main Breaker Load Center
Built with a shielded copper bus bar. UL listed.